The true Dissolved Air Flotation

Physical/chemical data

Flotation clarification is a mechanical disconnection process: microscopic air bubbles (best sized 30 – 60 µm – generate a high pressure reaction, releasing neutral particles. Together they rise to the surface. Clarifiers and sedimentation aids accelerate this process.

Dissolved air flotation (DAF)  or micro-flotation is based on the following physical laws:

1. Henry’s law

p = H  x  p

p = partial pressure of gas phase
x = mole fraction of the gas in the liquid phase
H = Henry constant

2. Stoke’s law for laminar flow

Ut = g (D – Dg) D2
18n

Ut = rise rate of bubble
D = bubble diameter
Dg = density of gas phase
g =  gravity constant
D2 = density of liquid
n = dynamic viscosity

The mixture of micro bubbles and particles rise to the surface with maximum speed.





TESTFLOT™ units can be operated with one of the following dissolved air processes:

Full stream • Partial stream • Recycle stream



TESTFLOT™ TE model with circular tank


TESTFLOT™ production TE series


TESTFLOT™ TE program

The size relates to INLET FLOW, process mode and SS load of raw water.

Process mode depends on hydraulic flow and load.

TESTFLOT™

Outdoor installation of two  units series TE  22.36  for a paper mill.


TESTFLOT™

Compact industrial  installation, TE-11-9 in a carpet factory. Part of two units installed in KSA.


TESTFLOT™ Turn Key units TE 8-2.2
installed in Jeddah, KSA.

Standard supply


Advantages

The gas/particle-mix quickly rises to the water surface thanks to a shallow depth of 0.6m. Thus, the bonding of micro bubbles and larger air bubbles is avoided.

Micro bubbles sized 40 – 60 µ within atmospheric pressure area – no low pressure condition has to be created.

Large surface for undisturbed floating sludge collected using rotary scoop.

No specific gas required to create micro bubbles.

100 % saturation by 4 – 6 bar air pressure in the “patent pending” HPT (High Pressure Tube).

Very short retention time of 2 – 3.5 min in the tank, thanks to already mentioned advantages.

No clogging.

High lifetime guaranteed.